Grasso V Type Reciptocating Compressors Manual

Reciprocating compressors Grasso Operating Manual 0089292gbr_2
Operating Manual | Grasso Reciprocating compressors
COPYRIGHT All Rights reserved. No part of this publication may be copied or published by means of printing, photocopying, microfilm or otherwise without prior written consent of Grasso. This restriction also applies to the corresponding drawings and diagrams.
LEGAL NOTICE This publication has been written in good faith. However, Grasso cannot be held responsible, neither for any errors occurring in this publication nor for their consequences.
2
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
SYMBOLS USED IN THIS MANUAL Danger! Stands for an immediate danger which leads to heavy physical injuries or to the death. Warning! Stands for a possibly dangerous situation which leads to heavy physical injuries or to the death. Caution! Stands for a possibly dangerous situation which could lead to light physical injuries or to damages to property. Hint! Stands for an important tip whose attention is important for the designated use and function of the device.
SAFETY INSTRUCTIONS General Caution! This manual must be carefull read and understood prior to servicing and running the compressor (package). For all safety instructions refer to Chapter 1, page 7 This user manual is written with great care, but the contractor/installer is held responsible for examining this information and to take care of possible additional and/ or deviated safety measures. Please consult your contractor (supplier). Hint! Before consulting your contractor (supplier) for any reason, make note of the data on the type plate fixed on the compressor, package and/or other package components.
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
3
Operating Manual | Grasso Reciprocating compressors
PREFACE This operating manual is meant for the end-users of Grasso reciprocating compressors and/or packages. This manual describes all safety instructions, global product information, required periodical inspections and a trouble shooting list. The users of this equipment have to follow all instructions as given in this manual. In case of any doubt, the supplier of the refrigeration plant should be consulted. For safety instructions refer to Chapter 1, page 7. Hint! GEA Grasso herewith declares that the machines mentioned are intended to be incorporated into a refrigeration package (= assembly of refrigeration components) or to be assembled with other equipment to constitute machinery covered by Machinery Directive 2006/42/EC and do therefore comply with the provisions of this directive that apply to partly completed machines. Furthermore it is not allowed to put the machines mentioned into service until the machinery in which it is to be incorporated, or, of which it is to be a component, has been found and declared to be in compliance with the provisions of Machinery Directive 2006/42/EC i.e. as a whole system including the machinery referred to in this declaration.
4
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
TABLE OF CONTENTS 1
2 3 4 5
SAFETY 1.1 REGULATIONS 1.2 MAINTENANCE AND REPAIRS 1.3 REFRIGERANT 1.4 OIL 1.5 OPERATING INSTRUCTIONS PRESSURE EQUIPMENT 1.5.1 Intended Use 1.5.2 Safety Notes and Warnings 1.5.3 Transport and Storage 1.5.4 Finishing and Installation INTRODUCTION 2.1 SURVEY COMPRESSOR TYPES INSPECTION 3.1 DAILY, WEEKLY AND MONTHLY INSPECTIONS 3.2 PERIODICAL INSPECTIONS TO BE CARRIED OUT BY YOUR CONTRACTOR (SUPPLIER) FAULT ANALYSIS 4.1 GENERAL MAINTENANCE 5.1 CONSULT YOUR CONTRACTOR (SUPPLIER)
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
7 7 7 7 8 8 8 9 9 9 10 10 11 11 12 13 13 14 14
5
Operating Manual | Grasso Reciprocating compressors
6
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
1 1.1
SAFETY Caution!
REGULATIONS
In compliance with the regulations of the Pressure Equipment Directive it is mandatory that no changes be made to the construction of pressurised parts such as the crankcase housing, suction filter housing, oil separator(s), etc.
Hint! It is the task of the contractor (supplier) to inform and explain to you as user, about the operation of the compressor (Package). Do respect all international, federal, state and local safety regulations/ legislations during inspection, trouble shooting and operating this compressor (package).
1.2
After having run the initial 100 operating hours,it is essential (in both new and modified plants) to replace the running-in filter element with the permanent filter element supplied. This operation is only to be carried out by well-trained and qualified personnel. Consult your supplier to carry out this service.
MAINTENANCE AND REPAIRS Warning! All maintenance and repairs have to be carried out only by your contractor (supplier), except the maintenance as explicitly mentioned in this manual.
This manual includes a check list for daily, weekly and monthly inspections. Temperatures and pressures need to be checked at several point (eg setting of all pressure safety switches). In case this manual does not give these values then your contractor (supplier) should instruct you with regard to their correct setiings. When reference is made to the plant manual, your contractor (supplier) should take care that your are instructed in being able to undertake proper inspections and trouble shooting.
Do not open the compressor for service.
Hint! In case of shut downs longer than 1 month, it is advisable to put warning labels on vital parts of the compressor saying that the plant is out-of-operation and must not be started up. Consult your contractor (supplier).
1.3
REFRIGERANT
The compressor/package must be filled with “REFRIGERANT“, to be able to operate.
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
7
Operating Manual | Grasso Reciprocating compressors
The type plates for identification of the pressure equipment looks like this:
Warning! For safety instructions in relation to the refrigerant used in this refrigeration plant, refer to separate information, to be supplied by your contractor (supplier).
1.4
OIL
The compressor/package must be filled with oil, to be able to operate.
fig.1:
Example type plate economizer ICH, compressor, package
fig.2:
Example Type plate oil separator
Warning! For safety instructions in relation to the oil used in this refrigeration plant, refer to separate information, to be supplied by your contractor (supplier).
1.5
OPERATING INSTRUCTIONS PRESSURE EQUIPMENT Hint! For pressure equipment (oil separator OS, housing suction gas strainer, Economizer ICH, compressor package) manufactured by Grasso according to the European Parliament's and the European Council's Pressure Equipment Directive 97/23/EG of 29 May 1997
General The following operating instructions according to the European Pressure Equipment Directive No. 97/23/EG (subsequently referred to as PED) describe how to handle the pressure equipment for finishing and installation. The pressure equipment is intended for installation in compressor packages or refrigeration plants and can be equipped with specific accessories during installation by the customer.
If the type plate is covered by finishing/installation, make sure that the information can be seen by the end user on another location on the pressure equipment.In case of queries regarding the operating instructions, please contact Grasso.
1.5.1
Intended Use
The pressure equipment described here may not be used for any other than the stated purpose. The equipment may only be installed by the finisher/ installer and not by the end user. If the pressure equipment is not used according to these regulations, safe operation of the equipment is not guaranteed.
The pressure equipment has been manufactured according to the requirements of the PED. Its design meets the requirements of the AD2000 regulations.
The finisher/installer or the operator and not the manufacturer is responsible for all personal injury and damage to property resulting from unintended use.
If applicable the finisher/installer (at installation in compressor package or refrigeration plants and equipping ready for operation) is obliged to prepare his own risk analysis and operating manual according to the European Pressure Equipment Directive 97/23/EG.
When not installed by Grasso the finisher/installer has to properly install accessories for the pressure equipment. The pressure equipment may not be damaged during installation and it shall be painted after installation.
8
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
The pressure equipment may only be filled with refrigerant of refrigerant groups L1 and L2, substance groups 1 and 2. The pressure equipment has to be installed in the compressor package or plant so that no vibrations or pulsations can be transmitted to the equipment.The connecting lines have to be installed to be tension free. The pressure equipment is not designed for dynamic loads.Where there is a risk of lightning strikes, the pressure equipment must be earthed. The finisher/installer has to include instructions for regular inspection of the pressure equipment in his instruction manual and has to define the end user's behaviour in case of damage. To avoid burns or frostbite, the pressure vessel may not be touched in the operating state. This can be achieved by means of contact guards. Install appropriate warning signs. Caution! Optionally supplied safety valves are only intended for the protection of the oil separator against excessive presssure caused by an external heat source during standstill. This device may not be used for the protection of the complete refrigeration system. (The finisher/installer has to equip the installation with a safety valve acc. EN 378)
for the new part). For recurring tests please refer to EN 378 T1 to T4 and local regulations.
1.5.3
Transport and Storage
Transport and store the oil separator in a dry environment. Ensure that the oil separator is not subject to damage relevant to its further use. In case of transport damage notify Grasso immediately.
1.5.4
Finishing and Installation
Design details can be seen in drawings at Grasso. Compare the identification (type plate) with the documentation included in the delivery before finishing, installing and equipping the oil separator. Mark the oil separator with the note 'Do not use' until the issue has been resolved with Grasso or an authorised third party (named authority according to the PED).
The oil separator may only be installed vertically. The foundation has to be of sufficient stiffness.
1.5.2
Safety Notes and Warnings
Visually inspect the pressure equipment with the naked eye for corrosion, scoring and similar damage. Check the equipment for shape consistency of the connection areas. In particular check and assess the sealing surfaces for possible damage such as scratches, scoring or similar. Keep corrosive substances such as acids away from the oil separator. Wall thicknesses may be no more than 1 mm less than those given in the drawing. Drain or suck off the medium (refrigerant/oil) prior to service and repair. These tasks may only be carried out by trained professionals and in compliance with the appropriate safety regulations, see standard EN 378. Carry out a detailed check of the previous operating history, when an oil separator that has already been in service is newly finished, installed and equipped. This includes visual inspection (as described above
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
9
Operating Manual | Grasso Reciprocating compressors
2
INTRODUCTION
2.1
SURVEY COMPRESSOR TYPES
Type * Series
General A survey of the full range of Grasso reciprocating compressors, is given in the table below. Please refer to the type plate of the compressor to determine the type of compressor you are currently using. Type *1 Series
Grasso V
Single stage
Two stage
Grasso V 300
Grasso V 300T
Grasso V 450
Grasso V 450T
Grasso V 600
Grasso V 600T
Grasso V 700
Grasso V 700T
Grasso V 1100
Grasso V 1100T
Grasso V 1400
Grasso V 1400T
Grasso V 1800
Grasso V 1800T
Grasso V 700 CM
Grasso V 700T CM
Grasso V 1100 CM
Grasso V 1100T CM
Grasso 12
Grasso VCM Grasso V 1400 CM
Grasso V 1400T CM
Grasso V 1800 CM
Grasso V 1800T CM
Grasso 35HP
-
Grasso 45HP
-
Grasso 55HP
-
Grasso 65HP
-
Grasso 212E *2
Grasso 2112E *3
Grasso 312E
Grasso 3112E
Grasso 10
Grasso 5HP
Single stage
Two stage
Grasso 412E
Grasso 4212E
Grasso 612E
Grasso 5112E
Grasso 912E
Grasso 6312E
Grasso 1212E
Grasso 7212E
-
Grasso 8412E
-
Grasso 9312E
-
Grasso 10212E
Grasso 212
Grasso 2112
Grasso 312
Grasso 3112
Grasso 412
Grasso 4212
Grasso 612
Grasso 5112
Grasso 912
Grasso 6312
Grasso 1212
Grasso 7212
-
Grasso 8412
-
Grasso 9312
-
Grasso 10212
Grasso 210
-
Grasso 310
Grasso 2110
Grasso 410
Grasso 3110
Grasso 610
Grasso 4210
Grasso 810
Grasso 6210
Grasso 12E
1 2 3
10
Type designation can be extended on the type plate of the compressor with K(Approval), M(Marine application), ... Grasso 12E compressor, with 2 cylinders. Grasso 12E compressor, with 2 low pressure cylinders and 1 high pressure cylinder.
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
INSPECTION DAILY, WEEKLY AND MONTHLY INSPECTIONS CHECK POINTS *
These inspections should be made during the operating periods.
monthly
FREQUENCY
weekly
3.1
daily
3
REMARKS *
The table below sums up all the points on the compressor that have to be inspected by the user. Warning!
Oil temperature max.
The compressor can be factory fitted with gauges and switches and/or with a micro processor system. In the case of a micro processor system, refer to the user manual(s) of the micro processor and/or to the plant manual. Consult your contractor (supplier).
Refer to plant manual, consult your contractor (supplier);

Max. __________oC Oil leakage of shaft seal
Suction pressure

Check against design conditions. Refer to plant manual, consult your contractor (supplier);

Min./Max. __________oC
Oil level in crankcase
Min. control oil pressure
4
5
REMARKS *5 Discharge pressure

Suction superheat Intermediate superheat

The oil should be transparently clear. A disappearing white colour points to dissolved refrigerant.
Discharge temperature max.

Range1.5-3.0 bar
Oil temperature min.
Between 25% and 75% height of the sight glass. For topping up oil, consult your contractor (supplier).

Colour of the oil
Lubricating oil pressure difference
monthly
weekly
daily
FREQUENCY CHECK POINTS *4


Setting 2.5 bar

Consult your contractor (supplier).
Consult your contractor (supplier): Min. __________bar
Cooling water temperature (if present)
Refer to plant manual, consult your contractor (supplier); Min./Max. __________oC R404A/R507 ≥ 15 K Other refrigerants ≥ 0K Min. __________oC
Max. 170 °C


During compressor standstill the lower part of the crankcase must remain warmer than the surroundings: ≥ 20 °C (NH3) Min. Actual condensing temperature + 10 K (≥ Tc + 10 K)
During the first 50 operating hours the compressor should be checked regularly for all the points mentioned above, at least twice every 24 hours and more frequently in cases where irregularities are found. Values of temperatures, pressures etc. as mentioned in this table, are given by the manufacturer. Actual values for this refrigeration plant, currently used can differ for the min./max. values as given in this table. Your supplier has to inform you about the actual/currently used values for this plant.
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
11
Operating Manual | Grasso Reciprocating compressors
3.2
PERIODICAL INSPECTIONS TO BE CARRIED OUT BY YOUR CONTRACTOR (SUPPLIER)
SAFETY Caution! For a safe operation of the compressor/package, your contractor (supplier) must carry out the checks as mentioned in the table below. Inspections by contractor
monthly
weekly
CHECK POINTS *6
daily
FREQUENCY
REMARKS
Wear (fraying, cuts etc.) and ensure that they do not touch the groove bottom. Condition of V-belts

Adjustment and operation of pressure safety switches

Capacity control (if provided)
Switching frequency of the compressor
6
12
Tension. Too low a tension gives rise to excessive flapping or oscillation in operation. For correct tension Grasso instruction sheet 0087516 must be used.
Refer to instructions of switch manufacturer.

The time lag between the unloading and loading of one cylinder or cylinder group should generally be at least 3 5 minutes.

The time interval between stopping and starting should be at least 10 minutes and between starting and restarting 15 minutes.
During the first 50 operating hours the compressor should be checked regularly for all the points mentioned above, at least twice every 24 hours and more frequently in cases where irregularities are found.
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
4 4.1
FAULT ANALYSIS GENERAL Warning! In case you find any problems in the installation, or one of the issues mentioned in the inspection list are not OK, (temperatures, oil level, pressures , ...), the compressor must be switched off. Your contractor (supplier) should inform you how the compressor has to be stopped safely. Refer also to the plant manual. Warning! If crankcase is frosted or wet: stop compressor immediately.
Instructions in case of any failure; 1. Stop compressor 2. Make note of the information on the type plate of the compressor 3. Consult your contractor (supplier) Typical faults, to be solved by your contractor (supplier) are: Typical faults FAULTS 1
Discharge pressure too high
2
Discharge temperature too high
3
Suction pressure too high
4
Suction pressure too low
5
All cylinders inactive while compressor is operating
6
Too high oil consumption
7
Too high oil pressure during normal operation at working temperature
8
Too low lubricating oil pressure
9
Too low or no control oil pressure (For Grasso V, Grasso (12)E and Grasso10 only)
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
13
Operating Manual | Grasso Reciprocating compressors
5 5.1
MAINTENANCE CONSULT YOUR CONTRACTOR (SUPPLIER)
All maintenance works are only to be carried out by the contractor (supplier). Example of works to be carried out by your contractor; 1. Leak testing 2. Evacuation, drying the refrigeration system 3. Initial oil charging 4. Initial refrigerant charging 5. Adjustment of all safety devices 6. Checking direction of rotation compressor 7. Installing drive guard 8. Initial start of the compressor 9. Preparing the compressor for a shut down period (>6 months) 10. Topping up oil 11. Draining and change of oil 12. Evacuation and purging compressor 13. Replacement of filters 14. Reset GMM (Grasso Maintenance Monitor) 15. Adjustment V-belt tension
14
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
Operating Manual | Grasso Reciprocating compressors
GEA Refrigeration Netherlands N.V. | 0089292gbr_2 | Generated 15.07.2013
15
We live our values. Excellence • Passion • Integrity • Responsibility • GEA-versity
GEA Refrigeration Technologies GEA Refrigeration Netherlands N.V. Parallelweg 27, 5223 AL ‘s-Hertogenbosch, The Netherlands Phone: +31 73 6203911 [email protected], www.gea.com
© GEA Group AG. All rights reserved. Subject to modification
GEA Group is a global engineering company with ­multi-billion euro sales and ­operations in more than 50 countries. Founded in 1881, the company is one of the largest providers of ­innovative equipment and ­process technology. GEA Group is listed in the STOXX® Europe 600 Index.

GEA Grasso V 600 580 8 1,500 310 474 1,363 933 922 1,042 GEA Grasso V 700 637 4 1,200 367 549 1,062 1,076 1,013 794 GEA Grasso V 1100 955 6 1,200 550 823 1,306 1,076 1,013 1,054 GEA Grasso V 1400 1,274 8 1,200 734 1,098 1,666 1,076 1,027 1,495 GEA Grasso V 1800 1,592 10 1,200 917 1,372 1,909 1,076 1,027 1,725 SINGLE-STAGE COMPRESSORS. Animation about the GEA Grasso V Series piston compressor. A trip in and around the industrial compressor.

Southern Sales & Services offer GEA Grasso open type reciprocating piston compressors with focus on high efficient ammonia compressors for refrigeration and heat pumps.

With the new GEA Grasso V reciprocating piston compressors series, GEA is heralding the start of a completely new era for the industrial refrigeration market. During the development of the GEA Grasso V series, GEA Grasso continually put itself in the position of the end user. Every component was assessed for the most important elements that contribute to a low Total Cost of Ownership like energy, maintenance and reliability with min. downtime.

Rotary screw compressors

Reciprocating Compressor Pdf

The result is not only the most effcient reciprocating compressor on the market but also a compressor with electronically controlled service intervals (extended as well as flexible) in order to reduce the Total Cost of Ownership without jeopardizing reliability. This new series replace the existing single stage series in a swept volume range from … up to … m³/h. Compound (two stage) compressors are now available.